Terzon Systems Inc. P. O. Box 835921 Richardson, TX 75083 (214) 234-8222 801SCAN Receiver Control System Our Scanning Programs All of our scanning software is built for the IBM/PC and compatibles hardware. You need at least 512K of RAM and DOS 2.0 or later. A hard disk is recommended but isn't required. Our programs make good use of color in their user interface, but you can use monochrome also. Each program uses a menu and function keys for easy control. Things you may want to do often that don't require a lot of input are done with function keys (F-Keys). For example, to start or stop scanning or searching, change the delay timer or delay mode, or perform simple operations, you would use a function key. To add new channels or banks, or perform other operations that require significant input, you'd use a menu screen. On-line help is fast and available from almost anywhere. The Demo Programs The demo programs are the actual working programs with the receiver communications portions disabled. Signal detection is simulated randomly. In every way possible, these programs are exactly what the working programs are. You can even work on your database using the demo program, and use it when the real one arrives! Since link speed (communications between the program and the receiver) controls the scan/search speed, the demo program speeds are simulated as closely as possible. The 801SCAN Program The 801SCAN program is designed for fast, flexible VHF Scanning. It is currently available for the ICOM R7000 and the ICOM R9000 receivers. The R7000 will scan at 14-15 frequencies per second at 9600 baud, the R9000 will do about 12 fps. The 801SCAN program will give you the quick and easy control of your receiver that you need to get the most of its superior RF capabilities. The program reads all database information into memory at startup to enable the fastest possible scanning. Here's what is stored in the basic database: 1800 Channel Definitions Each Channel definition contains a frequency, receive mode/bandwidth (AM, FMN, etc.), a 22-character description, and a lockout status. Counts are also maintained for number of times scanned and number of times active, for reporting activity. 200 Bank Definitions A Bank definition consists of a 22-character description. Each channel belongs to a Bank. A Bank in the R7000 program contains up to 99 channels (the number of memories) the R9000 program banks contain up to 100 channels. 100 Search Ranges A Search Range definition contains a start frequency (the lower limit), a stop frequency (the upper limit), a step or increment, receive mode and a 20-character text description. An enable flag (set to Yes or No) for each range tells the program whether to search this range when the Search F-Key is pressed. 500 Auto-Search Frequencies This database is used to collect active frequencies in an unattended Search. The frequencies can be marked so that you can search again for new activity, ignoring the ones already investigated or already in your Channels database. 801SCAN Function Keys Here is a list of the functions keys available on the 801SCAN program . F1 Help This key will pop up the on-line help window. You can get context-sen- sitive help from almost anywhere in the program. F2 Bank Scan Mode Lets you select the Bank Scan Mode. Modes include: Multi-Bank Sets 1, 2, or 3. Select one of these to scan a set of selected banks. Use the Bank menu item to select the members (Banks to include) of each set. Single-Bank Mode. Causes the system to scan the currently selected single bank. Use Banks to choose the bank. When a Bank is selected, the currently selected bank is automatically de-selected, providing an instant Bank switch. Priority Bank Mode. In this mode, the selected Bank is re-scanned, starting from Channel 1, every n seconds. The re-scan interval timer is set on the Parameters screen. F3 Scan/Stop This key starts the scan. If you are already scanning, it stops the scan. F4 Search/Stop This key starts a search. If you are already searching, it stops the search. F5 Continue This key causes the scan/search to continue without waiting for the delay timer to expire. If you are stopped, it resumes your last scan/search where you left off. F6 Lockout If you are scanning and stopped on a signal, this key will set the lockout flag for this channel, and continue the scan. You can reset the lockout using the Channels screen. F7 Delay Time Select This function key brings up a pop-up window with the delay values you defined on the Parameters screen. Select one by pressing on your choice. F8 Select Short Step Puts up a pop-up for you to select a short step (as defined on Parameters). Alt-F8 selects the Long Step F9 Short Step Down Allows manual frequency control. This sets the receiver to the current frequency minus the current short step. Alt-F9 uses the Long Step. F10 Short Step Up This sets the receiver to the current frequency plus the short step. Alt-F10 uses the Long Step. Alt-F1 Set Direction This very useful key lets you toggle the direction of your scan or search. If you accidentally pass up a interesting signal, just press this key to reverse your scan/search! Alt-F2 Set Frequency/Mode Brings up a pop-up to set the current freq/mode of your receiver. Alt-F3 Single-Step Scan Performs a one-channel scan, setting the next channel and stopping. Alt-F4 Single-Step Search Performs a one-step search. Alt-F5 Save to Disk Saves the current Parameters, Channels and Banks to disk. Alt-F7 Selects Delay Mode Choose from one of these delay modes: End-Delay. Scan/search continues after the signal drops for the current delay timer value. Start-Delay. Scan/search continues after being stopped on a signal for the timer value, or if the signal drops for the Start-Delay timer interval (set on the Parameters screen). Fixed-Delay. Stops on a signal for the timer value even if the signal subsequently drops. 801SCAN Screens The 801SCAN screens are available from the Menu at the top of the screen. Here is a brief description of their functions. To familiarize yourself with them, use the demo program and try them out. They are designed to be easy to understand and use. Press F1-Help to get more information when you need it. Play around, using the system is the quickest way to become expert at it! Bank The Bank screen is used to select the Banks you want to scan. You can set up the banks for the currently selected Bank Scan Mode, or work on another one. Channels The Channels screen is used to add new Bank and Channel definitions, delete Banks or Channels, or just update the information such as description. Parameters This screen is used to set up the less often changed operational para- meters. Here you set up the link port and speed, and your own list of delays and steps that you can then choose with Function Keys while running. Use F1-Help on each field for more information. Auto-Search Run This screen is used to run an Auto-Search. This feature lets you search a range or ranges for activity while unattended. It keeps a list of what it found for you to work with using the Auto-Search Frequencies screen. The Frequencies screen lets you review the findings and move the frequencies to a Bank, delete them or mark them as Lockouts so you can search the ranges again for new activity! Auto-Search Search This screen is used to define your Search Ranges. These ranges are used for Auto-Search and well as the normal (F4) interactive search. Logging Activity Report Use this screen to get channel activity reports. These reports show the percentage of scans that a channel is active. By scanning unattended with delay set to 0.0 seconds, you can profile the activity of a set of channels. Use this feature to find the least/most busy repeater or other channel of a group. You can save the reports to disk for future reference. Logging Activity Clear This screen is used to reset the scanned/active counts for Channels. Logging Event Logfile Lets you select the current filename to log Events to. Event logging is an advanced feature that allows you to track the detection of all signals as you scan, the time carrier was detected and the duration of the signal, sorted and grouped by frequency! Memories, Upload and Download The Download screen lets you re-program your receiver's memories from data in your Channels database. The Upload feature lets you read the receiver's memories into a Bank you specify. Find This screen lets you search your Channels for a text string (searches the descriptions) or for a frequency. Use it to find out if a particular freq- uency is already in your database, or look for all Channels with "fire" or "repeater" in their descriptions. A list of Channels meeting Find's search criteria are displayed in a window. You can make a new Bank from them, or just set the receiver to one using an F-Key. Text Read This screen lets you read Banks/Channels information for an ordinary text file. The file can be in practically any format, including columnar (which means that the information fields can be identified by their positions in the line) or delimiter (which means a special character such as tab or comma separates the information fields). The Text Write functions lets you write your Bank/Channels information to ordinary disk files for manipulation with a text editor, spreadsheet, etc. More About the Programs The 801 programs are professionally-developed and designed for the professional and advanced radio hobbyist. You may not feel that you need all of their features now, but the power is there as your needs grow. The programs make it as simple as possible to do basic things like scanning and searching. Interfaces You must have an interface, a special device to convert your computer's RS-232 signals into the type the receiver requires, to run a control program with your receiver. We provide an excellent interface for the ICOM receivers, it requires no power supply and is completely self- contained. You simply connect it to your 25-pin RS-232 connector (use an adapter if you have 9-pin) and the other end connects to the receiver. If you already have an interface, you can use our program with it. The ICOM CT-17 is suitable for the 801HF program where squelch detection isn't required. The interface from other radio-control system manufac- turers will work with our program, so you can upgrade your capabilities without buying another interface. Also note that if you have an R71 or other receiver that does not come with the CI-V interface, you'll have to get the ICOM UX-14 converter to use our systems. Installation Installation of the 801 programs and interfaces is very simple. You'll be up and running in minutes! Warranty All Terzon Systems interface/cables are warranted for 1 year from date of purchase. Our software warranty is unique. If you can find a program error, we'll correct it and return you an upgrade free of charge! Ordering You may order by mail using check, money order or VISA /MasterCard, or by telephone using VISA or MasterCard. If you get our voice mail system when you call, use your touch tone phone to access mailbox 801 and follow the instructions. Orders are generally processed weekly. All prices include shipping by USPostal Service Priority Mail, which provides two-day service to most locations. If you pay by check, your order will be delayed about a week. If you want your order filled within two working days, we offer that service at an extra charge. If we can't fill your order that fast, we'll refund the extra charge. We now offer the user manual as a separate item. If you purchase a demo or user manual, you can deduct your price from your program order. We'll omit the manual from your shipment if you already purchased one. ------------------------------------------------------------------------ Name ___________________________ Address _________________________ City _____________________________ State ______________ Zip__________ Telephone ______________________ ___ 801HF Program Only . . . . . . $94.95 ___ 801HF Program with Interface/Cable . $144.95 ___ 801HF Demo Program . . . . . . . $5.00 ___ 801HF Instruction Manual Only . . . $16.00 ___ Rush Order (2 day processing). . . $18.00 Deduct ____ for Demo _____ for Manual ______ TX residents add 8.25% sales tax . . . . ______ Shipping/Handling FREE TOTAL: _______ Credit Card Info ____ M/C ____VISA Card Number _______________________ Expires ___________ Signature________________________________ Terzon Systems Inc. P. O. Box 835921 Richardson TX 75083 (214) 234-8222 24 hour voice mail. Use touch tone phone to access mailbox 801.